Skip to content

Country

Jetters for Compatability Dropdown

General Purpose

4018 Industry Leader

US Jetting

The 4000 PSI at 18 GPM unit is US Jetting's most popular hydro jetting machine for good reason. As the industry leader, it has set the standard in ...

View full details

4025 Max Versatility

US Jetting

The 4025 [4000 PSI 25 GPM] is US Jettings most versatile jetting machine. This drain cleaning machine performs best in 4"-24" lines. With 4000 PSI ...

View full details

3030 Medium Flushing

US Jetting

The 3030 [3000 PSI 30 GPM] is a powerful and versatile sewer jetter unit. From city sewers to large diameter culverts, this machine takes everythin...

View full details

3040 Power Flushing

US Jetting

The 3040 [3000 PSI 40 GPM] is an industrial strength machine designed to clean large sewers or storm drains. Powered by a 115 HP Tier 4 Diesel Engi...

View full details

2065 Max Flushing

US Jetting

The 2000PSI 65GPM unit is the most popular unit for municipalities. With massive flushing power, it is mainly used to move heavy debris in large pi...

View full details

FAQ

Category

What is a good guide for hose size and corresponding pressure and flow needed to tackle for each pipe size?

1” Hose - 2000-3000 PSI – 50 GPM+ Flow - Pipe Size 12"-48"

3/4” Hose - 2000-3000 PSI - 30-40 GPM Flow – Pipe Size 10"-48"

5/8” Hose - 3000-4000 PSI – 20-25 GPM Flow - Pipe Size 8"-36”

1/2" Hose - 3000-6000 PSI - 12-18 GPM Flow – Pipe Size 4"-24"

3/8” Hose - 3000-4000 PSI - 10-12  GPM Flow – Pipe Size 3"-6"

1/4” Hose – 3000-4000 PSI - 5-8 GPM Flow - Pipe Size 2"-4"

3/16” Hose - 3000-4000 PSI – 5-8 GPM Flow – Pipe Size 3/4"-1 1/2"

How often should the hoses and fittings be inspected for wear?

Inspect before each use. Look for cuts, bulges, leaks, and worn areas. Replace immediately if damaged.

Why is my jetter not getting up to pressure?

Possible causes: worn pump seals, clogged nozzle, bypass is open, or insufficient water supply. Check and address each in turn.

How should the machine be winterized to avoid freeze damage?

For a full tutorial, see our Antifreeze Instruction video here. Drain all water from pump, hoses, and nozzles. Run antifreeze through the pump system if storing in freezing conditions.

Can I recirculate my water between jobs to avoid having to antifreeze my unit in freezing temperatures?

Yes, hook your sewer hose up to your return to tank line. Increase the revs of your engine (on Tier 4 go to pressure setting 2 which should be around 2000PSI, but for Tier 3 jetters running at idle is sufficient) and turn your water valve on. Make sure you have no leaks in order for the water to effectively recirculate.